Effect of biomedical waste on human health

Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.incinerator-scrubber.com/ 

Nanjing Clover Medical Technology Co.,Ltd.

Equipment Technical Specifications

Model

TS30S

Picture

 

Feed Capacity

78 Liters for primary chamber

Burning Rate

Typical 30 kgs per hour

Burning Time Each Feed

0.5 hour

Voltage

220V

Power

0.5Kw

Fuel

Diesel oil

Burner

Diesel Oil Burner, 2 sets

Feed Mode

Manual

Fuel consumption (Oil)

Typical 8 Kgs/Hour

External Dimensions

90 x 90 x 150cm (main body)

Internal Dimensions

Dia.50 x 40cm(Main Chamber)

Waste combustion chamber

78Liters

Article Combustion Chamber

50Liters

Oil Tank Capacity

100 Liters

Door Opening

25 x 25cm

Chimney

3.0M

Gross Weight

1200kgs

Chamber Material

Refractory Concrete 

Max.

80,000Kcal/Hr.

Operation Technical Specifications

Chamber temperature

8000C -10000C

Chamber Anti-Rate

13500C

Residency time

0.5 Sec.

Burning efficiency

>98 percent

Waste Lower Calorific Power

ways of disposing solid waste

3000Kcal

HICLOVER Incinerator/Parts Range

Main Feature

Medical Waste Incinerators

HICLOVER 10-500kgs/Hr.Double Combustion Chambers

Single Combustion Chamber

Small, Cheap,10-20kgs/Hr.

Three Combustion Chambers(Optional)

3 Chambers for high risk waste

Pet Cremation Equipment

For Pet(small/big) Cremation Business

Animal Incineration Equipment

For additional animal incineration

effect of biomedical waste on human health


Items/Model

TS100(PLC)

TS150(PLC)

TS300(PLC)

TS500(PLC)

Burn Rate (Average)

100 kg/hour

150 kg/hour

300 kg/hour

500 kg/hour

Control Mode

PLC Auto.

PLC Auto.

PLC Auto.

PLC Auto.

Combustion Chamber

1200L

1500L

2000L

3000L

Internal Dimensions

120x100x100cm

150x100x100cm

170x120x100cm

210x120x120cm

Secondary Chamber

600L

750L

1000L

1500L

Smoke Filter Chamber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Feed Mode

Manual

Manual

Manual

Manual

Voltage

220V

220V

220V

220V

Power

1.38Kw

1.69Kw

2.57Kw

4.88Kw

Diesel Oil Consumption (kg/hour)

Ave.20.4

Ave.24.2

Ave.33

Ave.44

Natural Gas Consumption (m3n/hour)

Ave.24.5

Ave.29

Ave.39.6

Ave.52.8

Temperature Monitor

Yes

Yes

Yes

Yes

Temperature Protection

Yes

Yes

Yes

Yes

Oil Tank

200L

300L

500L

500L

Chimney

10Meter

10Meter

14Meter

14Meter

Chimney Type

Stainless Steel

Stainless Steel

Stainless Steel

Stainless Steel

1st. Chamber Temperature

800℃–1000℃

800℃–1000℃

800℃–1000℃

800℃–1000℃

2nd. Chamber Temperature

1000℃-1200℃

1000℃-1200℃

1000℃-1200℃

1000℃-1200℃

Residency Time

2.0 Sec.

2.0 Sec.

2.0 Sec.

2.0 Sec.

Gross Weight

6000kg

8500kg

11000kg

16000kg

External Dimensions

260x150x180cm

300x160x190cm

400x210x300cm


The incinerator units shall include a temperature based electronic combustion control system that utilizes temperature and other data to inform automated or programmed cycling through the standard burn cycle: pre-heat, burn with waste addition, burn completion, cool-down. The system shall be capable of varying auxiliary fuel and air supply in both combustion chambers to achieve optimum combustion conditions. As far as practicable, the incinerator shall be of a plug and play type for ease of installation and commissioning in remote locations.
“The control system shall have a separate push button-based work station, which shall be located adjacent to the loading bay and protected from weather and impact damage. The system shall allow for rapid and straightforward intervention by the operator if the automatic system is not achieving the desired results during a burn cycle. 

 CE Certification Pass

HICLOVER Solution for Fighting COVID-19 with CE Certification.
 
1. Medical Waste Incinerator(Containerized Mobile Incinerator|Top Loading Incinerator)
 
2. Auto Roll Air Filter for Clean Room2021-02-21

450x210x300cm