Items/Model A1500 A2400 A4000 A5500
Burning Rate *animal 90 kgs/Hr. 150 kgs/Hr. 200 kgs/Hr. 400 kgs/Hr.
Feed Capacity *animal 120 kgs 200 kgs 300 kgs 500 kgs
Equipment Weight 7000 kgs 8300 kgs 13000 kgs 16500 kgs
Primary Chamber (Liters) 1500 2400 4000 5500
Secondary Chamber (Liters) 500 1200 1500 1500
External Dimensions (cm) 240x170x380 260x220x420 320x220x460 360 x 220 x 475
Internal Dimensions (cm) 150x100x96 220x110x100 257x147x108 300 x 147 x 125
Oil Tank(Liters) 500 500 500 500
Door Opening (cm) 59 x 81 90 x 110 108 x 128 108 x 128
Chimney (M) 10 10 14 14
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES

Key Features:  * All versions with Dual combustion chamber.  * Stainless Steel chimney/stack, long lifetime. *according to sequence * High temperature, long lifetime of incinerator.  * Free or minimal installation on site.  * PLC Control Plane. *according to order  * New Design for pet animal cremation company.  * One year warranty on incinerator and parts in stock.

Kazakhstan Medical Incinerators

Basic Info.

Export Markets:Global

Additional Info.

Trademark:clover

Product Description

Items Specification
YDC Model YD-10C / YD-20C / YD-30C / YD-50C
Main Product List Primary Combustion Chamber
Secondary Combustion Chamber
Mix Combustion Chamber
Smoke Filter Chamber
Incinerator Common Control Case
Stainless Steel Chimney
Italy oil/gas burner: 02 units
Oil Tank (if oil fuel)

Nanjing Clover Medical Technology Co., Ltd..

Animal Waste Incinerator

Basic Info.

Model NO.:animal pet incinerator for sales
Export Markets:Global

Product Description

Items/Model A1500 A2400 A4000 A5500
Burning Rate *animal 90 kgs/Hr. 150 kgs/Hr. 200 kgs/Hr. 400 kgs/Hr.
Feed Capacity *animal 120 kgs 200 kgs 300 kgs 500 kgs
Equipment Weight 7000 kgs 8300 kgs 13000 kgs 16500 kgs
Primary Chamber (Liters) 1500 2400 4000 5500
Secondary Chamber (Liters) 500 1200 1500 1500
External Dimensions (cm) 240x170x380 260x220x420 320x220x460 360 x 220 x 475
Internal Dimensions (cm) 150x100x96 220x110x100 257x147x108 300 x 147 x 125
Oil Tank(Liters) 500 500 500 500
Door Opening (cm) 59 x 81 90 x 110 108 x 128 108 x 128
Chimney (M) 10 10 14 14
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES

Nanjing Clover Medical Technology Co., Ltd..

Incinerator Made by Clover

Basic Info.

Type:Medical Waste Incinerator
Export Markets:Global

Additional Info.

Trademark:clover

Product Description

Main Characteristics:  1, Using fever of gasifying combines burning technology. It applied to burn several kinds of medical waste, like syringes, infusion set, medical waste incinerator provider, medical equipment manufacturers, medication waste in china, mobile hazardous waste incinerators, mobile incinerator medical waste, disposable dressing, and also small animal, some town waste, like newspaper, tree leaves.  2, Closed vacuum-wide operation, applicable to deal with infectious medical waste and to prevent secondary pollution.  3, Complete design, easy to move to different location.  4, Combustion burner from China or Italy.

Items/Model YD-10C YD-20C YD-30C YD-50C
Burning Rate (kgs/Hour) 10 kgs/Hr. 20 kgs/Hr. 30 kgs/Hr. 50 kgs/Hr.
Feed Capacity (kgs) 40 kgs 40 kgs 50 kgs 80 kgs
Equipment Weight 1200 kgs 1200 kgs 1800 kgs 2200 kgs
Primary Chamber (Liters) 200 200 250 400
Secondary Chamber (Liters) 140 140 140 140
External Dimensions (cm) 170x140x160 170x140x160 170x140x190 180x160x200
Internal Dimensions (cm) 55x55x65 55x55x65 55x55x85 70x70x85
Oil Tank(Liters) 50 100 100 150
Door Opening (cm) 38 x 48 38 x 48 38 x 48 45×55
Chimney (M) 5 5 5 5
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES

Incinerator

Basic Info.

Model NO.:50 kgs per hour
Pullution Sources:Solid Waste Processing
Processing Methods:Combustion
Export Markets:Global

Additional Info.

Trademark:clover

Product Description

Principle of the Incinerator equipment is incineration/combustion/burn.

Items/Model TS50(PLC)
Burn Rate 50 kg/hour
Feed Capacity 100kg
Control Mode PLC
Combustion Chamber 560L
Internal Dimensions 100x80x70cm
Secondary Chamber 280L
Smoke Filter Chamber Yes
Feed Mode Manual
Voltage 220V
Power 0.7Kw
Oil Consumption (kg/hour) 12.1–24
Gas Consumption (m3/hour) 9.9–26.1
Temperature Monitor Yes
Temperature Protection Yes
Oil Tank 100L
Feed Door 70x55cm
Chimney 5Meter
Chimney Type Stainless Steel
1st. Chamber Temperature 800 degree –1000 degree
2nd. Chamber Temperature 1000 degree -1200 degree
Residency Time 2.0 Sec.
Gross Weight 4500kg
External Dimensions 230x130x155cm
 

Considering Environmental Protection requirements and principles, almost all incinerator have secondary combustion chamber (after-burn, post-combustion), even when third combustion chamber. The secondary burner burn the Exhaust gas from primary combustion chamber, this technology make sure adequate combustion, few black smoke and smell.  The updated incinerator technology focus on Exhaust gas treatment to eliminate Hazardous material and other purpose from incinerator, like heat recovery (waste to energy), save fuel cost, PLC Automation operation.  In some Developed countries, some new waste treatment method such as High-temperature cooking, waste carbonization, crushing sterilization technology is instead of incineration technology.

Pyrolytic Incinerator

Basic Info.

for Animal:All
Dosage Form:Incineration
Type:Cremation
Function:Cremation
Export Markets:Global

Additional Info.

Trademark:nanjing clover
Origin:Nanjing Clover

Product Description

Research and Markets: Waste: A Handbook for Management 

The breadth of data included in this volume will make it the most comprehensive coverage of waste in the marketplace. It focuses on all of the main areas such as household waste (compostable material, newspaper, glass, textiles, household chemicals, plastic, water, e-waste), industrial and pet waste incinerator, pet. Crematory, pets cremation equipment, pets crematorium, pharmaceutical burning incinerator, pharmaceutical>waste label, pharmaceuticals waste, societal waste (metals, building, tires, medical battery, hazardous mining, nuclear, ocean, military, and space), and the future of landfills and incinerators. Including all the issues associated with waste in 1 volume will help lead to comparisons, synergistic solutions, and a more educated society. In addition to a detailed coverage of waste, this book will offer the best methods for managing the problems through recycling, incineration, landfill and other processes.

Twin Chamber Incinerator

Basic Info.

Pullution Sources:Solid Waste Processing
Processing Methods:Combustion
Export Markets:Global

Additional Info.

Trademark:clover

Product Description

Items/Model YD-10C YD-20C YD-30C YD-50C
Burning Rate (kgs/Hour) 10 kgs/Hr. 20 kgs/Hr. 30 kgs/Hr. 50 kgs/Hr.
Feed Capacity (kgs) 40 kgs 40 kgs 50 kgs 80 kgs
Equipment Weight 1200 kgs 1200 kgs 1800 kgs 2200 kgs
Primary Chamber (Liters) 200 200 250 400
Secondary Chamber (Liters) 140 140 140 140
External Dimensions (cm) 170x140x160 170x140x160 170x140x190 180x160x200
Internal Dimensions (cm) 55x55x65 55x55x65 55x55x85 70x70x85
Oil Tank(Liters) 50 100 100 150
Door Opening (cm) 38 x 48 38 x 48 38 x 48 45×55
Chimney (M) 5 5 5 5
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES

Nanjing Clover Medical Technology Co., Ltd., Neighborhood in Nanjing city, China.

Two Chamber Medical Waste Incinerator

Basic Info.

Model NO.:tempreture of the stoker moving grate incinerator
Export Markets:Global

Product Description

Key Features:  * All models with Dual combustion chamber.  *according to order  * High fever, long life of incinerator.  * Free or minimal installation on site.  * PLC Control Plane. *based on order  * New Design for pet animal cremation business.  * One year warranty on incinerator and parts in stock. 

Key Features:  * All models with Dual combustion chamber.  * Stainless Steel chimney/stack, long life. *according to order  * High fever, long life of incinerator.  * Free or minimal installation on site.  * High burn rate, from 10kgs to 500kgs large medical incinerators, large scale clinical waste incinerator, bio medical incenarator manufacturer in china, bio medical waste incinerators manufacturers china, per hour, up to 6ton per day.  * PLC Control Plane. *based on order  * New Design for pet animal cremation business.  * One year warranty on incinerator and parts in stock. 

Application Scope:  1. Hospital& clinic: Iatric Waste, Infectious Waste, Dressing, Bio-Waste, Medicine.  2. Slaughter House &Pet Hospital &Farm: Dead Animal, Bio-Waste.  3. Community & Sea Port & Station: Municipal Solid Waste, etc.  4. Laboratories, Remote Locations, Disaster Relief Operations, Animal Cremation

Items/Model YD-30 YD-50 YD-100 YD-150
Burning Rate (kgs/Hour) 30 kgs/Hr. 50 kgs/Hr. 100 kgs/Hr. 150 kgs/Hr.
Feed Capacity (kgs) 60 kgs 150 kgs 200 kgs 300 kgs
Equipment Weight 2300 kgs 4000 kgs 4300 kgs 7000 kgs
Primary Chamber (Liters) 360 900 1200 1500
Secondary Chamber (Liters) 200 200 500 500
External Dimensions (cm) 145x90x175 200x160x230 220x180x360 240x170x380
Internal Dimensions (cm) 100x60x60 120x90x85 130x100x90 150x100x96
Oil Tank(Liters) 200 300 300 500
Door Opening (cm) 48 x 60 62 x 80 55 x 80 59 x 81
Chimney (M) 5 5 10 10
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES

Efficient stove technology Alleviates N. Kenya’s medical waste problem

WAMBA, Kenya, June 30 (Thomson Reuters Foundation) – Poor weather, security threats and poor roads have made disposing of the Wamba district hospital’s medical waste a challenge.

The nearest incinerator is about 200 kilometres (125 miles) away and “travelling was not possible during heavy rains because linking roads were cut off by flooding,” stated Stephen Lesrumat, a medic in the hospital.

But now the north-central Kenyan hospital has a solution to its problems, and a means of cutting climate changing emissions and deforestation: A high-efficiency medical waste incinerator that uses just a fifth the fuel of a traditional incinerator.

The wood burner, which takes advantage of strong winds in the area to push the flames, borrows technology from fuel-efficient stoves. It can safely eliminate waste produced by the Wamba hospital and by 22 other health centers in Samburu County, stated Lesrumat and Ibrahim Lokomoi, the facility’s engineer.

“It has reduced the burden of traveling outside the county to eliminate medical waste,” Lesrumat said, sparing hospitals a potentially dangerous build-up of medical waste during periods when roads are impassible.

During previous flooding periods, when hospital waste could not be transported, “I was stressed because the waste is toxic,” Lesrumat stated. “It could lead to health and environment damage if it accidentally spilled into the community. ”

Run-ins with al Shabaab militants can also be a danger for some healthcare workers in Kenya driving long distances in their jobs, medics said.

“Northern Kenya is extremely expansive and has numerous challenges that the government struggles to provide services,” stated Onyango Okoth the assistant commissioner of Samburu County.

Currently the Wamba incinerator handles between 5 and 20 kilograms of medical waste a day.

As the burner works, a young employee clad in protective clothing flips open the lid of the chamber to monitor the process of incineration.

Seeing the last batch of waste is all but eliminated, he reaches for a cone containing a variety of used rubber gloves, syringes and polythene waste, pours in some of the waste, mixes it with a forked pole and then replaces the lid to allow the incineration to continue.

The Centers for Diseases Control in Kenya estimates that every patient admitted in a hospital generates at least 0.5 kilograms of medical waste.

The next step, Kenyan clean energy experts say, may be to start incinerating waste using more sustainable sources of energy, such as solar energy.

“Kenya is investing heavily in alternative energy sources,” said Johnson Kimani of the Kenya Climate Change Working Group. “Solar and biogas should be factored into medical waste incineration if the government is committed to its pledge of achieving a green market. ”

James Lebasha, of the International Medical Corps, which helped assemble the Wamba incinerator, said the burner might be just the first for the area.

“We hope to build more units in morthern Kenya to allow communities access this service,” he said. (Reporting by Kagondu Njagi; editing by Laurie Goering:Please credit the Thomson Reuters Foundation, the charitable arm of Thomson Reuters, that covers humanitarian news, climate change, women’s rights, trafficking and corruption.

“We hope to build more units in morthern Kenya to enable communities access this service,” he said. (Reporting by Kagondu Njagi; editing by Laurie Goering :; Please credit the Thomson Reuters Foundation, the charitable arm of Thomson Reuters, that covers humanitarian news, climate change, women’s rights, trafficking and corruption. Visit www.trust.org/climate)

from: http://www.reuters.com/article/2015/06/30/kenya-medical-energy-idUSL8N0ZG1M220150630

Pyrolytic Dual Chamber Incinerator Small Size:Burning Rate:30-45 kg/hr;Maximum Load Capacity:400 kg

Items/Model

TS50(PLC)

Picture

Principle

Solid Waste Incineration

Burn Rate

30-45 kg/hour

Control Mode

PLC(Programmable Logic Controller Incinerator)

Combustion Chamber

560L

Internal Dimensions

100x80x70cm

Secondary Chamber

280L

Smoke Filter Chamber

Yes

Feed Mode

Manual

Voltage

220V

Oil Consumption (kg/hour)

Typical 13.3

Gas Consumption (m3/hour)

***

Temperature Monitor

Digital Display

Temperature Protection

Yes

Oil Tank

800L

Feed Door

70x55cm

Chimney

5Meter

Chimney Type

Stainless Steel

1st.

800℃–-1000℃

2nd. Chamber Temperature

1000℃-1200℃

Residency Time

2.0 Sec.

Gross Weight

4500kg

External Dimensions

HICLOVER – Medical Environmental 

230x130x155cm


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.incinerator-scrubber.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

Medium Size:Burning Rate:60-80 kg/hr Pyrolytic Dual Chamber Incinerator

Items/Model

TS100(PLC)

Picture

Principle

Waste Incineration Treatment

Burn Rate

60-80 kg/hour

Control Mode

PLC(Programmable Logic Controller Incinerator)

Combustion Chamber

1200L

Internal Dimensions

120x100x100cm

Secondary Chamber

600L

Smoke Filter Chamber

Yes(Dry Scrubber)

Feed Mode

Manual

Voltage

220V

Oil Consumption (kg/hour)

Typical 20.4

Gas Consumption (m3/hour)

***

Temperature Monitor

Digital Screen

Temperature Protection

Yes

Oil Tank

1100L

Feed Door

80x60cm

Chimney

10Meter

Chimney Type

Stainless Steel

1st.

800℃–-1000℃

2nd. Chamber Temperature

1000℃-1200℃

Residency Time

2.0 Sec.

Gross Weight

6000kg

External Dimensions

260x150x180cm


The requirement is for a pyrolytic double-chamber incinerator. The incinerator shall be capable of using diesel 
fuel as a supplemental fuel oil.
It should incorporate an Air Pollution Control (APC) System suitable for basic emission control.
The proposed incinerators shall be appropriate for critical harsh environmental conditions, suitable for rapid 
deployment, and different climate zones (e.g. desert, tropical country, mountain, etc.) in which there are several 
variations of the relative natural forces (e.g. temperature, humidity, wind, etc.) for a minimum period of 10 years 
if the specified maintenance schedule is followed.
The incinerators should be supplied assembled, whenever possible, and all parts and components should be 
packaged on pallets in order to be transported via road, air (via helicopters or air-cargoes, e.g. MI8 or C130) 
and via sea in a 20’ ISO sea shipping containers.

HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.incinerator-scrubber.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

Large Size Burning Rate:150-200 kg/hr Solid Waste Equipment Primary and Secondary Combustion Chamber Incinerator

Items/Model

TS500(PLC)

Picture

Principle

Waste Incineration Treatment

Burn Rate

150-200 kg/hour

Control Mode

PLC(Programmable Logic Controller Incinerator)

Combustion Chamber

2700L

Internal Dimensions

190x120x120cm

Secondary Chamber

1300L

Smoke Filter Chamber

Yes

Feed Mode

Manual

Voltage

220V

Oil Consumption (kg/hour)

Average 28

Gas Consumption (m3/hour)

***

Temperature Monitor

Digital Screen

Temperature Protection

Yes

Oil Tank

1400L

Feed Door

90x80cm

Chimney

10Meter

Chimney Type

Stainless Steel

1st.

800℃–-1000℃

2nd. Chamber Temperature

1000℃-1200℃

Residency Time

2.0 Sec.

Gross Weight

15000kg

External Dimensions

The air supply should be controlled efficiently;
Flame contact with all the gases should be achieved;
The minimum combustion temperature of the primary chamber should not be less than 850°C;
The primary combustion chamber should be equipped with a means to provide supplemental liquid fuel supply.
The primary chamber should be cold face refractory lining, with a minimum thickness 100 mm.
The following conditions should be met in the secondary combustion chamber:
The air supply should be controlled efficiently;
Flame contact with all the gases should be achieved;
The size of the secondary chamber should be properly designed to ensure that the gas retention time should not be less than 2 seconds;
The secondary chamber should be cold face refractory lining, with a minimum thickness 100 mm;
The chamber should incorporate an integrated combustion burner air fans with automatically controlled distribution;
The gas temperature, as measured against the inside wall in the secondary chamber (not in the flame zone) should not be less than 1,100°C;

400x210x300cm(without chimney)

HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.incinerator-scrubber.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

hiclover incinerator 100-150kgs per hour

Model

YD-100

Picture

Burning Rate

100-150 kgs/hour

Main Combustion Chamber

2000 Liters

Secondary Combustion Chamber

500 Liters

Feed Mode

Manual

Voltage

220V/380V

Power

2.5Kw

Fuel Type

Diesel Oil

Burner

Italy Original

Oil Consumption (Diesel Oil)

Typical 28 kg/hour

Gas Consumption (Natural Gas)

***

Internal Dimensions

180x115x98 cm (primary chamber)

External Dimensions

270x185x280cm (without chimney)

Temperature Monitor

Yes

Oil Tank Capacity(if Petroleum fuel)

200 Liters

Door Opening

55 x 80cm

Chimney Length

6.0 Meters

Chimney Type

Steel

Equipment Gross Weight

9000 kgs

Operation Technical Specifications

Main Chamber Temperature

800℃–-1000℃

Secondary Chamber Temperature

1000℃-1200℃

Residency Time

2.0 Sec.

Burning Efficiency

>98 percent

Waste Lower Calorific Power


HICLOVER – Medical Environmental 

3500Kcal


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.incinerator-scrubber.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

Large General waste incinerator Burn Rate up to 250kg per hour

Items/Model

TS300(PLC)

Principle

Waste Incineration Treatment

Burn Rate

Average 250 kg/hour

Control Mode

PLC(Programmable Logic Controller Incinerator)

Combustion Chamber

2000L

Internal Dimensions

170x120x100cm

Secondary Chamber

1000L

Smoke Filter Chamber

Yes

Feed Mode

Manual

Voltage

220V

Power

2.5Kw

Oil Consumption (kg/hour)

Typical 28(DO)

Gas Consumption (m3/hour)

***

Temperature Monitor

Digital Screen

Temperature Protection

Yes

Oil Tank

1000L

Feed Door

80x60cm

Chimney

10Meter

Chimney Type

Stainless Steel

1st.

800℃–-1000℃

2nd. Chamber Temperature

1000℃-1200℃

Residency Time

2.0 Sec.

Gross Weight

11000kg

External Dimensions

HICLOVER – Medical Environmental 

400x210x300cm(without chimney)


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.incinerator-scrubber.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

Supply, Installation and commissioning of Waste Incineration system

The proposal must include the comprehensive description of the whole system: Total cost of supply, Installation, commissioning, Automatic feeding, automatic de- ashing through performance, and efficient gas cleaning system (wet, dry or higher temperature ceramic filters), continuous emission monitoring system (CEMS), and all    other    accessories, Control    panel    for    all     components     of     the system, Troubleshooting alarm system covering all components of the system, to notify the operator to the fault which may arise during the operation, and to perform immediate corrective action, Emergency Stop button which can easily shut off / shut down all major part of the system in the event of emergency situation. Primary chamber ability / Average capacity per patch Load: 3000 Kg, Incineration capacity per hour 400 Kg/hr. , Loading system: side loading, Number of burners: minimum 7 burners, (5 to main room, 2 for secondary room ), Fuel: Diesel, The system should work continuously for at least 12 hours every day, The primary room: Heavy- duty anodized Rust resistant steel casing with minimal thickness 7mm. Painted with heat reflective paint, internal heavy duty refractory cement lining and insulation for maximum heat retention. Price of supply, installation, operation cost including fuel consumption per hour, and price of other consumable materials treatment materials (intake rate per hour and unit price each), delivery time till operation, Layout for the whole three components and gas cleaning systems, considering minimum are required for the system “containing enough area for handling and operation ”, Confirmation letter that gas emission from the system after gas cleaning should comply with Saudi regulations for gasoline emissions (stamped letter and Emission comparison table showing the emissions from the system in comparison with Saudi regulations “attached”)

Page

The proposal should include the complete description of the whole system: Total cost of supply, Installation, commissioning, Automatic feeding, automatic de- ashing during operation, and efficient gas cleaning system (wet, dry or high temperature ceramic filters), continuous emission monitoring system (CEMS), and all    other    accessories, Control    panel    for    all     components     of     the system, Troubleshooting alarm system covering all components of the system, to notify the operator for the fault that may arise during the operation, and to perform immediate corrective action, Emergency Stop button that can easily shut off / shut down all major part of the system in case of emergency situation. Primary chamber capacity/ Average capacity per patch Load: 3000 Kg, Incineration capacity per hour 400 Kg/hr., Loading system: side loading, Number of burners: minimum 7 burners, (5 for primary chamber, 2 for secondary chamber), Fuel: Diesel, The system should work continuously for at least 12 hours per day, The primary chamber: Heavy- duty anodized Rust resistant steel casing with minimum thickness 7mm. painted with heat reflective paint, internal heavy duty refractory cement lining and insulation for maximum heat retention. Cost of supply, installation, operation cost including fuel consumption per hour, and cost of other consumable materials treatment materials (consumption rate per hour and unit cost each), delivery time till operation, Layout for the whole three units and gas cleaning systems, considering minimum are required for the system “including enough area for operation and handling”, Confirmation letter that gas emission from the system after gas cleaning should comply with Saudi regulations for gas emissions (stamped letter and Emission comparison table showing the emissions from your system compared with Saudi regulations “attached”)

Page | 4

•    Incinerator should have two (2) chambers: primary chamber with five (5) burners to incinerate materials and the secondary chamber with two (2) burners to incinerate exhaust gases.
•    The main body of the incinerator shall be stainless steel and the outside insulation thickness of not less than 7 mm made from zinc or phosphate for temperature insulation
•    The main gate of the Incinerator should be 150 mm thick and strength not less than 170 kg/m3. The door should be automatic with remote to operate.
•    The Incinerator should be designed in accordance of the environmental regulation followed in country of  origin or  as per  Saudi Arabian PME Regulations.
•    The incinerator should have fuel storage with capacity of 1000 liter.
•    The incinerator shall have the capacity to operate with temperature up to 1300 OC in the primary chamber and it can remove the residual while the incinerator is in operation
•    The inside body of the incinerator should have insulation layer made of calcium with thickness of 50 mm while the thickness of the internal surface should be 100 mm in order to stand with 1300 OC.
•    All the supporting braces of the incinerator shall be installed on stainless steel.
•    The gap between the internal and external body shall be filled with the special insulation material.
•    The exhaust shall not stay more than two (2) seconds in the secondary chamber and this chamber shall be built with high density of ceramic oasis.
•    There should be a stack with four (4) meter from the top surface of the incinerator and can be removed and installed.
•    The incinerator shall have control device for exhaust gases so that the emission shall meet the PME source standards
•    The power supply should be 220 – 380 Volts, 60 Hz. and the incinerator shall be provided with control panel showing the following:

Page | 5

•    Temperature of primary and secondary chamber.
•    Condition of pressure gages.
•    Alarm showing if there is any leakage or misconducting in the electricity.
•    Indicator for overloading the burner.
•    Timer for automatically switching off the incinerator.
•    All the incinerator parts including fuel pumps, fans, valves and pipes can be operated in high ambient temperature (50OC)
•    All  parts  of  the  incinerator  shall  be  painted  in  one  color  which  should  be resistant to high humidity, high temperature and high dust / sandstorm.
•    3 years warranty with spare parts and technical supply and
•    10 years warranty for  providing spare  parts starting from the  date  of first warranty expiry
•    Provide all the list of consumable items like, filters, sorbents, etc.

The bidder shall provide all necessary details related to the facility dimensions, space area required for the whole system and all operation requirements, Details about required facility (hanger) including Layout, civil work and electromechanical details including electricity, water pipes, fuel pipes, tanks, etc. Complete Drawing & 3D drawing Clearly Show All Sections and Details of the System. List of spare parts and checklist. Required Operation staff, Fuel consumption rate of the whole system. Since our project is a turnkey project including Design, Build & Operate of central incineration facility covering all the above mentioned details and we have to coordinate all civil works and necessary requirements to operate the system.

an incinerator for our dental clinics

2. A camera post-combustion gases :
Cold filter plugging point -10 ° C max.

DIESEL AND FOOD TANK BURNER

The fuel tank will be found annexed into the dugout roof incinerator at a bund and have the following characteristics:

• Capacity: 1,200 liters
• Made of sheet steel for easy wall installation cubeto
Point above 55C inflammation.
• gas or diesel burner (must be specified in the sequence ), monobloc horizontal flame, electronic ignition, secure, permanent ventilation, control valve and isolation valve.
• Meter and level switch

The incinerator has a intake of 16.2 liters of gas to burn waste generated operation 10 hours a week expected in two burning, so that autonomy will be 7.5 weeks. The reservoir will have an outlet and an inlet for return. Pipes for oil will drive the black steel pipe with longitudinal electric resistance welded 3/4 ” DN 20mm diameter. In the tank outlet pipe retainer debris filter, with aluminum body is put, aluminum cup and stainless steel sieve with holes 100 microns in diameter .advise about the ingestion rates, is that for both chambers, or per room?

After 10 minutes, the afterburner is temperature:

•Spinning on the toaster combustion chamber, which ensures the output of the gasification of waste. The operating time of the burner is programmable according to the type of waste, using a flexible mechanical timer from 1-60 minutes.
• air injection nozzles made of refractory steel with a flow control valve.
a. watertight door for manual loading of waste.
• A timer adjustable time delay for each burner control.
• fibrous insulation panels made of calcium silicate with a depth of 75mm.

an incinerator for our dental clinics.The incinerator must comply with ” Technical Standard NTON 05-015-02 Management and Solid Waste Disposal Hazardous co go ”, as well as meeting international standards performance standards for new stationary sources and emissions from the Environmental Protection Agency United States ( Environmental Protection Agency EPA ) Incinerators Medical and Hospital infectious waste ( HMIWI its acronym in English ) and the standards of the World Health Organization (WHO ).

According to point 8.5.1.3 of this NTON 05-015-02 incinerator must have the following:

” Incinerators equipped with a camera primary and a secondary combustion, equipped with burners capable of achieving complete combustion of waste and widespread destruction of harmful and toxic chemicals (dioxins and furans amongst others), attached to the solid waste bioinfectious.

a) primary combustion chamber, it requires a temperature of 800 ° C and one hour live to be ruined waste generated gas and ash, including dioxins can create cancer is found.

b ) In the secondary combustion chamber must reach temperatures around 1,100º C and have to be operated with a residence time of the flue gases of a minimum of two seconds. To treat gas flow and entrained particles, before being discharged into the air, should be added towers chemical washing, cyclones, filters. ”

The incinerator installed must comply with the design to ensure the destruction of all hazardous, biological, industrial waste as well as many others. Combustion ” PYROLYTIC ” allows management of the gasification of waste and avoid significant discharge of black smoke and fine powder during loading. Additionally, it allows, regular and complete combustion of the waste.

The main advantages are a controlled combustion that ensures the absence of smoke, color, smell or dust. It is also automatic, so you don’t need supervision and has a low fuel consumption.

The incinerator contains:

1. A combustion chamber :
• A controller with digital display for temperature afterburner.
• Automatic Burner ( gas or diesel must be specified in the order ) with flames diving in one piece monoblock with an electronic ignition system, permanent venting valve and isolation valve.

• combustion flooring made in carborundum, preventing binding of glass and slag.

Afterburner gases

• The afterburner is powerful sheet steel flange connection.
• The electrical panel meets current standard.
• automated start of combustion air fan.

After two hours, the end of ” combustion cycle ” automatically guarantee:

• The closing of primary air servomotor.
A. burner combustion, low power.
• thermal insulation panels made of fibrous silicates and calcium with a depth of 85 mm.
d . A smoke evacuation duct .

The incinerator meets as indicated on waste incineration.

During charging, opening the door ensures instant shutdown fan primary and secondary air. At the conclusion of the combustion cycle the fan primary / secondary air and burner continues to operate for two hours to protect the burners and to cool the oven. Following this time the program automatically turns off the setup completely.

FUEL USE

This installation shall take for operation of diesel with the following characteristics:

Density at 15 ° C (max / min ) 0.88 / 0.82 kg / l
They will not burn plastics, packaging except that the amount so small that gases need not receive any therapy, secondary combustion chamber into 1100C handles everything. .

The chimney is 350 mm inner diameter and a height of 8.13m will with hatch analysis.

Combustion chamber

• The combustion chamber is thick steel plate (3 to 10 mm ) with reinforcements, especially built.
• Obtaining the combustion cycle during which no tracking service ( duration 2 hours ) is required.

The combustion cycle ensures:
• Pressure gauge and filler cap
• Special high fever.

OPERATION

The operation thereof is as follows:

• Charging waste.
• Front loading with watertight door mounted on hinges, locking screw wheel, elastic gasket and an insulation lined.
• Fan distribution primary and secondary air, the air flow regulation is effected by way of valves and actuators on automatic cycle commands.

Control and regulation
Kinematic viscosity at 40 ° c ( min / max) 2 / 4.5 mm2 / s
• An inner lining of refractory concrete comprising 42% of H² 03 (alumina ) and 100 mm thick walls.
• Output for venting diameter 1 1/2 ”
Control Panel dustproof, painted sheet with chopped paint comprising:
• Internal filling refractory concrete with very higher alumina content ( 65% H² 03) and a thickness of 150 mm.
Weight sulfur 0.2 % max.
• A secondary air injection is scheduled and ensures ideal oxygen content.
b . An injection device air for total re- combustion of these gases.

c . An input device cooling of the combustion gases.
• A circuit breaker switch for each motor ( fans and burners).
• Color : Light + dark blue.

• Capacity: 1,200 liters
• Made of sheet steel for simple wall installation cubeto
• Output for ventilation diameter 1 ½ ”
• Pressure gauge and filler cap
• Meter and level switch

The incinerator has a consumption of 16.2 liters of diesel hour to burn waste generated operation 10 hours a week expected in two burning , so that autonomy will be 7.5 weeks . The reservoir will have an outlet and an inlet for return. Pipes for oil will drive the black steel pipe with longitudinal electric resistance welded 3/4 ” DN 20mm diameter . In the tank outlet pipe retainer debris filter , with aluminum body is placed , aluminum cup and stainless steel sieve with holes 100 microns in diameter .advise on the consumption rates, is that for both chambers, or per chamber?

medical waste materials incinerator

company. Our products main for small waste output. For hospital straight, local at hospital, or portable/mobile

incinerator to a single website when end-customer request. incinerator without smoke and smelting for the environment.

capapcity 500kg per day. Could you specify the point of petroleum fuel? By this you mean petrol or diesel?

an incinerator acceptable for chemcial waste containers. Capacity about 100 kgs per hour with a scrubber.1- One system of

medical waste materials incinerator
– Capacity : 100 kg
We specify that we’re interested in mobile incinerators for hospital use.

capapcity 500kg per day. Could you specify the point of oil fuel? By this you mean petrol or diesel?
with dieseil burner.we managed to get a walk in Algeria, and we hope to export to other countries in Africa.
we specify that we are interested in mobile incinerators for hospital use.

waste disposal incinerator

2. What’s your minimum capacity and maximum capacity incinerator.

3. You do provide secodn hand incinerator in good working condition.

Incinerator but the size of room > 2000 x >1200 mm. Prepare for burn LIQUID Waste +/- 20 liter/hr.
C: How many batch can we place in each day basis per 24 hours.
The chamber of the incinerator should be able to hold about 200 – 250 kilogram of waste at a specified time.
Dthe majority of systems will be run on petrol, so I want to understand the necessary pressure of gasoline in psi to operate the machine with no problem.
A;  Batch Capacity for every version, how much load can we place in 1 time. I need tio under stand in duration of batch load one time that I can ut in Kgs.

Refractory Concrete Incinerator

Disinfecting/sterilizing the contaminated medical wastes, main combustion chamber, post combustion chamber, heat exchanger, ash removal components and flue gas treatment systems, together with the following details:

Hourly capacity of the system:           from 250 up to 500 Kgs/ hour

Duration of operation:                        from 14 up to 18 hrs/ day

Fuel type to be used:                         Diesel or other

Calorific value of the waste:               3500 up to the maximum limit kcal/ Kg

Minimum operating temperature of main chamber: 1000 degrees celcius

a smaller  capacity of 150 to 250  kg/feed capacity

2 medical waste incinerators model YD-50, 150 kg feed capability, 220/380 V, 50 Hz c/w 5 mtr. chimney.
solicito un horno crematorio para mascotas, de una capacidad de 80 kl, aprox. solo una unidad, especificaciones tecnicas, totalmente industrial, atte. erika martinez peru

•             Using diesel as fuel

•             Capacity 50kg per hour

•             chambers material: Refractory Concrete

•             Number of chambers: 2

•             Manual feed

BIO WASTE INCINERATOR

50 kg/  hour  capacity incinerators

·        Burning Rate: 50kos/hr

·        Feed Capacity:  150kqs

·        Main Combustion  Chamber:  900 Dimensions

·        Secondary  Combustion  Chamber:  300 Dimensions

·        Mix Combustion  Chamber:  Yes

·        Smoke Filter Chamber:  Yes

·        Feed Mode: Manual

·        Power: 0.7Kw

·        Fuel Type: Diesel Oil/ Natural Gas/LPG

·        Internal Dimensions:  120 x 90 x 85cm (primary  chamber)

·        External  Dimensions:  200 x 160 x 310cm (without  chimney)

·        Burning  Efficiency:  >98%

small  scale medical waste  incinerators.The necessary burning capacity of these incinerators are 10 kg and 15 kg/hr. The fuel oil using for those incinerator is diesel oil.

Containerized Mobile Incinerator Medical Waste Incinerator Model CA50

HICLOVER – Containerized Mobile Incinerator Medical Waste Incinerator Model CA50


Model

CA50

Picture

Waste Treatment

Medical Waste Incineration Treatment

Feed Capacity

Average 100 kgs per feeding

Burning Rate

Average 50 kgs per hour

Burning Time per Feed

Average 2 hour

Control Mode

PLC(Programmable Logic Controller Incinerator)

Voltage

220V

Power

1.0 Kw

Gas

Diesel oil

Burner

Italy Burner

Feed Mode

Manual

Temperature Monitor

Digital Screen

Fuel consumption (Oil)

Average 16.9 Kgs/Hour

Internal Dimensions

100x80x70cm (Primary Chamber)

External Dimensions

230 x 130 x 155cm (main body)

Waste combustion chamber

560Liters

Post Combustion Chamber

280Liters

Oil Tank Capacity

200 Liters

Door Opening

70 x 50cm

Chimney

5.0M

Gross Weight

4500kgs

Chamber Material

Firebrick,Refractory Concrete

Max.

166,000Kcal/Hr.

Operation Technical Specifications

Solid Chamber temperature

8000C -10000C

Gas Chamber temperature

10000C -12000C

Chamber Anti-Rate

17500C

Residency time

2.0 Sec.

Burning efficiency

>98%

Waste Lower Calorific Power

3000Kcal


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.incinerator-scrubber.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

Small Medical Waste Incineraotr for COVID-19 Bio Hazardous Medical Waste

HICLOVER – Medical Environmental 

Model

YD-20

Picture

Burning Rate

Average 20 kgs/hour

Feed Capacity

Average 60 kgs/feeding

Primary Combustion Chamber

360 Liters

Secondary Combustion Chamber

200 Liters

Mix Combustion Chamber

Yes

Smoke Filter Chamber

Yes

Feed Mode

Manual

Voltage

220V

Power

1.0 Kw

Fuel Type

Diesel Oil/ Natural Gas/LPG

Burner

Italy Original

Oil Consumption (Diesel Oil)

Average 13.3 kg/hour

Gas Consumption (Natural Gas )

***

Internal Dimensions

100 x 60 x 60cm (primary chamber)

External Dimensions

145 x 90 x 260cm (without chimney)

Temperature Monitor

Yes

Oil Tank Capacity(if Petroleum fuel)

200 Liters

Door Opening

48 x 60cm

Chimney Length

5.0 Meters

Chimney Type

Stainless Steel

Equipment Gross Weight

2300 kgs

Operation Technical Specifications

Primary Chamber Temperature

800℃–-1000℃

Secondary Chamber Temperature

1000℃-1200℃

Residency Time

2.0 Sec.

Burning Efficiency

>98%

Waste Lower Calorific Power

3000Kcal

Wearing a face mask to keep out the coronavirus has become an essential part of everyday life for many people 
around the world, but the huge amount of waste being created as the single-use items are tossed aside has the 
potential to become an ecological disaster.

How to deal with discarded face masks, which number in their millions or even billions, is another headache for 
Chinese authorities already caught between containing the viral disease and limiting the economic damage caused by it.

The country’s inadequate medical waste treatment capabilities have also been put under the spotlight, environmental experts said.

Environment and health authorities say masks and other protective gear, especially items used by medical personnel and 
people infected with the coronavirus, should be treated as clinical waste, and sterilised before being incinerated at high 
temperatures at dedicated facilities.

While it is difficult to get an exact figure on the number of discarded masks, it is reported that the volume of medical 
waste in Wuhan, the city in which the epidemic began in December, had quadrupled to more than 200 tonnes a day last 
week, according to mainland Chinese media reports.

The total amount of medical waste gathered across Hubei province on February 24 totalled 365 tonnes, of which 60 per 
cent came from hospitals, the report said.

By comparison, Wuhan produced 17,000 tonnes of medical waste in the whole of 2018, according to the country’s top 
environment watchdog.

Eric Liu, a toxic waste specialist at Greenpeace’s Beijing office, said China had a huge shortage of waste disposal facilities, 
specifically those capable of handling clinical waste.

“The waste treatment capacity in China, especially in terms of medical and hazardous waste, is barely enough to cope 
with everyday needs, let alone the country’s biggest public health crisis in decades,” he said.

While the environment ministry said most medical waste was being properly dealt with in major cities, just 31 per cent 
of the country’s 629,000 tonnes of medical waste were treated in 2015, up from 24 per cent in 2008, Xinhua reported 
last year, citing an industry study.

Du Huanzheng, director of the Recycling Economy Institute at Tongji University in Shanghai, also expressed concerns 
over the widening supply-demand gap in medical waste treatment, but said a large number of new facilities were being built or planned.

“The disposal of medical waste is a major part of the battle against the outbreak, which is a wake-up call for the government 
to speed up the construction of new facilities and research into waste treatment technologies,” he said.

The coronavirus outbreak could be the catalyst for expanding the medical waste sector and lead to the building 
of more incineration facilities, the experts said.

They said combustion remained the preferred means for disposing of medical waste in China, although industrialised 
countries were phasing out incinerators due to health and environmental concerns.

Masks could be split into three categories, Liu said. While clinical waste must be disposed of at dedicated incineration
 facilities, masks used by healthy people could be tackled in a similar way as household waste, which was burnt in industrial furnaces, he said.

The real challenge came from those used by people who were placed under home quarantine or others with mild symptoms, he said.

“There is a grey area over this kind of used mask, which are not under the jurisdiction of medical institutions but should 
be treated in accordance with standards for medical waste.”

In Wuhan, authorities are scrambling to find solutions to the challenge. The environment ministry said the city’s five incinerators 
for household waste disposal and various industrial furnaces at cement and other factories had also been assigned to help clear 
the garbage backlog, which stood at about 190 tonnes as of February 24.

According to a report by China Economic Daily, Wuhan is rushing to build more medical waste treatment plants near hospitals, 
including ones near Huoshenshan, Leishenshan and Jinyintan hospitals that will treat nine, 15 and four tonnes of clinical garbage respectively on a daily basis.

A total of 17 temporary storage facilities for medical waste, with a combined capacity of more than 1,000 tonnes, have also been built.

While authorities had to transfer some of the garbage produced in Wuhan to neighbouring cities for incineration, they have also 
tried to enlist help from waste treatment companies around the country.

China Shipping Group and a company in Anhui deployed a number of mobile medical waste incineration cabins to Wuhan last month, Xinhua reported.

The incinerators, each of which is capable of processing five tonnes of waste a day, were first used in 2003 during the Sars outbreak.


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.incinerator-scrubber.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

Containerized Type Pre-Assembled Mobile Hospital Waste Incinerator Model CA100

Items/Model

CA100

Picture

Principle

Medical Waste Incineration Treatment

Burn Rate

Average 100 kg/hour

Feed Capacity

Average 200kg/feeding

Control Mode

PLC(Programmable Logic Controller Incinerator)

Combustion Chamber

1200L

Internal Dimensions

120x100x100cm

Secondary Chamber

600L

Smoke Filter Chamber

Yes

Feed Mode

Manual

Voltage

220V

Power

1.3 Kw

Oil Consumption (kg/hour)

Average 20.4 Kgs/Hour

Gas Consumption (m3/hour)

***

Temperature Monitor

Digital Display

Temperature Protection

Yes

Oil Tank

200L

Feed Door

80x60cm

Chimney

5Meter

Chimney Type

Stainless Steel

1st.

800℃–-1000℃

2nd. Chamber Temperature

1000℃-1200℃

Residency Time

2.0 Sec.

Gross Weight

6000kg

External Dimensions

HICLOVER – Medical Environmental 

260x150x180cm


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.incinerator-scrubber.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

Three Combustion Chambers MEDICAL WASTE INCINERATOR

Model

WS-35

Picture

Burning Rate

Typical 35 kgs/hour

Feed Capacity

Typical 80 kgs

Primary Combustion Chamber

460 Liters

Secondary Combustion Chamber

200 Liters

Third Combustion Chamber

200 Liters

Smoke Filter Chamber

Wet Scrubber System

Feed Mode

Manual

Voltage

220V

Power

2Kw

Fuel Type

Natural Gas/LPG

Burner

Italy Original

Oil Consumption (Diesel Oil)

***

Gas Consumption (Natural Gas )

Typical 24 m3n/hour

Internal Dimensions

110 x 70 x 60cm (primary chamber)

External Dimensions

160 x 100 x 180cm (without wet scrubber)

Temperature Monitor

Yes

Oil Tank Capacity(if oil fuel)

***

Door Opening

50 x 50cm

Chimney Length

5.0 Meters

Chimney Type

Stainless Steel

Equipment Gross Weight

5000 kgs

Operation Technical Specifications

Primary Chamber Temperature

800℃–-1000℃

Secondary Chamber Temperature

1000℃-1200℃

Residency Time

2.0 Sec.

Burning Efficiency

>98 percent

Waste Lower Calorific Power

Primary chamber:
Heavy duty mild steel casing, High quality Refractory lining and insulation 01 x natural gas ignition burners (automatic) 01 x temperature 

sensor points with complete internal fans.
Secondary Chamber:
Heavy duty mild steel casing, high quality refractory lining and insulation 01 x natural gas burners (automatic) with complete 01 internal fans. 

02 Sec gas residence times.
Third Chamber:
Heavy duty mild steel casing, high quality refractory lining and insulation 01 x natural gas ignition burners (automatic) with complete internal 

fans. 02 Sec gas residence time.

HICLOVER – Medical Environmental 

3000Kcal


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.incinerator-scrubber.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

Small Scale Medical Waste Coronovirus (Covid 19) Incinerator 30 kgs per hour Model TS30 PLC Car Control

Items/Model

TS30(PLC)

Picture

 

Burn Rate

Average 30 kg/hour

Feed Capacity

Average 60kg per feeding

Control Mode

PLC(Programmable Logic Controller Incinerator)

Car Control and Display

Combustion Chamber

330L

Internal Dimensions

75x75x60cm

Secondary Chamber

180L

Smoke Filter Chamber

Yes

Feed Mode

Manual Feeding

Voltage

220V

Power

0.5Kw

Oil Consumption (kg/hour)

Average 13.3

Gas Consumption (N.G, m3n/Hour)

Average 16

Gas Consumption (L.P.G, m3n/Hour)

Average 11.7

Temperature Monitor

Four Digital Display

Temperature Protection

Yes

Oil Tank

200L

Feed Door

55x50cm

Chimney

5Meter

Chimney Type

Stainless Steel

1st.

800℃–-1000℃

2nd. Chamber Temperature

1000℃-1200℃

Residency Time

2.0 Sec.

Gross Weight

3000kgs/4000kgs

External Dimensions


HICLOVER – Medical Environmental 

175x120x140cm


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.incinerator-scrubber.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

Incinerator Light Shipping Weight Small-Scale Hospital Medical, Containerized Mobile Incinerator Optional

Light Weight Small-Scale Medical, Mobile Optional Type

Model Capacity/Burnning Rate For Hospital SickBed No. Fuel Type Qty. Ready for Shipping New Production  Shipping Volume Shipping Weight Delivery Location
TS30 average 30kgs per hour Average 150 SickBed Diesel Oil 1 set 5 days 20sets/2 weeks 5 m3 3000 kgs Shanghai Port
TS50 average 50kgs per hour Average 250 SickBed Diesel Oil 1 set 7 days 20sets/2 weeks 7m3 4500 kgs Shanghai Port
TS100 average 100kgs per hour Average 500 SickBed Diesel Oil 1 set 7 days 15sets/2 weeks 10m3 6000 kgs Shanghai Port
TS150 average 150kgs per hour Average 750 SickBed Diesel Oil 5 sets 7 days 15sets/2 weeks 13m3 7500 kgs Shanghai Port
YD10 average 10kgs per hour Average 50 SickBed Diesel Oil 2sets 7 days 20sets/2 weeks 3m3 1200 kgs Shanghai Port
YD20C average 20kgs per hour Average 100 SickBed Diesel Oil 2sets 7 days 20sets/2 weeks 6m3 2000 kgs Shanghai Port
YD50C average 50kgs per hour Average 250 SickBed Diesel Oil 2sets 7 days 20sets/2 weeks 7m3 2300 kgs Shanghai Port
YD30 average 30kgs per hour Average 150 SickBed Diesel Oil 1 set 5 days 20sets/2 weeks 5m3 2300 kgs Shanghai Port
YD30 Small average 30kgs per hour Average 150 SickBed Diesel Oil 2sets 5 days 20sets/2 weeks 3m3 1500 kgs Shanghai Port
YD50 average 50kgs per hour Average 250 SickBed Diesel Oil 2 sets 5 days 20sets/2 weeks 8m3 4500 kgs Shanghai Port
YD100 average 100kgs per hour Average 500 SickBed Diesel Oil 1 set 10 days 15sets/2 weeks 13m3 6000 kgs Shanghai Port
YD150 average 150kgs per hour Average 750 SickBed Diesel Oil 1 set 10 days 15sets/2 weeks 17m3 7500 kgs Shanghai Port
YD300 average 300kgs per hour Average 1500 SickBed Diesel Oil     10sets/2 weeks 20m3 9000 kgs Shanghai Port
YD500 average 500kgs per hour Average 2500 SickBed Diesel Oil     5sets/2 weeks 27m3 13000 kgs Shanghai Port
CA 50 Mobile Containerized average 50kgs per hour Average 250 SickBed Diesel Oil 2 sets 15 days 10sets/2 weeks 28m3 7000 kgs Shanghai Port
                   
1. Information High frequency change, for reference only.                  
2. Price as formal quotation and technical details and business term                  

HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.incinerator-scrubber.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

Medical Waste Incinerator in Stock for Coronavirus Disease COVID-19

HICLOVER Medical Waste Incinerator in Stock(Finished and Semi-finished and New Production)
Model Capacity/Burnning Rate For Hospital SickBed No. Fuel Type Qty. Ready for Shipping New Production 
TS30 average 30kgs per hour Average 150 SickBed Diesel Oil 1 set 5 days 20sets/2 weeks
TS50 average 50kgs per hour Average 250 SickBed Diesel Oil 1 set 7 days 20sets/2 weeks
TS100 average 100kgs per hour Average 500 SickBed Diesel Oil 1 set 7 days 15sets/2 weeks
TS150 average 150kgs per hour Average 750 SickBed Diesel Oil 5 sets 7 days 15sets/2 weeks
YD10 average 10kgs per hour Average 50 SickBed Diesel Oil 2sets 7 days 20sets/2 weeks
YD20C average 20kgs per hour Average 100 SickBed Diesel Oil 2sets 7 days 20sets/2 weeks
YD50C average 50kgs per hour Average 250 SickBed Diesel Oil 2sets 7 days 20sets/2 weeks
YD30 average 30kgs per hour Average 150 SickBed Diesel Oil 1 set 5 days 20sets/2 weeks
YD30 Small average 30kgs per hour Average 150 SickBed Diesel Oil 2sets 5 days 20sets/2 weeks
YD50 average 50kgs per hour Average 250 SickBed Diesel Oil 2 sets 5 days 20sets/2 weeks
YD100 average 100kgs per hour Average 500 SickBed Diesel Oil 1 set 10 days 15sets/2 weeks
YD150 average 150kgs per hour Average 750 SickBed Diesel Oil 1 set 10 days 15sets/2 weeks
YD300 average 300kgs per hour Average 1500 SickBed Diesel Oil     10sets/2 weeks
YD500 average 500kgs per hour Average 2500 SickBed Diesel Oil     5sets/2 weeks
CA 50 Mobile Containerized average 50kgs per hour Average 250 SickBed Diesel Oil 2 sets 15 days 10sets/2 weeks
HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.incinerator-scrubber.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

Medical Waste Incinerator for Coronavirus Disease COVID-19


HICLOVER Medical Waste Incinerator in Stock(Finished and Semi-finished and New Production)
Model Capacity/Burnning Rate For Hospital SickBed No. Fuel Type Qty. Ready for Shipping New Production 
TS30 average 30kgs per hour Average 150 SickBed Diesel Oil 1 set 5 days 20sets/2 weeks
TS50 average 50kgs per hour Average 250 SickBed Diesel Oil 1 set 7 days 20sets/2 weeks
TS100 average 100kgs per hour Average 500 SickBed Diesel Oil 1 set 7 days 15sets/2 weeks
TS150 average 150kgs per hour Average 750 SickBed Diesel Oil 5 sets 7 days 15sets/2 weeks
YD10 average 10kgs per hour Average 50 SickBed Diesel Oil 2sets 7 days 20sets/2 weeks
YD20C average 20kgs per hour Average 100 SickBed Diesel Oil 2sets 7 days 20sets/2 weeks
YD50C average 50kgs per hour Average 250 SickBed Diesel Oil 2sets 7 days 20sets/2 weeks
YD30 average 30kgs per hour Average 150 SickBed Diesel Oil 1 set 5 days 20sets/2 weeks
YD30 Small average 30kgs per hour Average 150 SickBed Diesel Oil 2sets 5 days 20sets/2 weeks
YD50 average 50kgs per hour Average 250 SickBed Diesel Oil 2 sets 5 days 20sets/2 weeks
YD100 average 100kgs per hour Average 500 SickBed Diesel Oil 1 set 10 days 15sets/2 weeks
YD150 average 150kgs per hour Average 750 SickBed Diesel Oil 1 set 10 days 15sets/2 weeks
YD300 average 300kgs per hour Average 1500 SickBed Diesel Oil     10sets/2 weeks
YD500 average 500kgs per hour Average 2500 SickBed Diesel Oil     5sets/2 weeks
CA 50 Mobile Containerized average 50kgs per hour Average 250 SickBed Diesel Oil 2 sets 15 days 10sets/2 weeks
HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.incinerator-scrubber.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

Medical Waste Incinerator for Coronavirus Disease COVID-19


HICLOVER Medical Waste Incinerator in Stock(Finished and Semi-finished and New Production)
Model Capacity/Burnning Rate For Hospital SickBed No. Fuel Type Qty. Ready for Shipping New Production 
TS30 average 30kgs per hour Average 150 SickBed Diesel Oil 1 set 5 days 20sets/2 weeks
TS50 average 50kgs per hour Average 250 SickBed Diesel Oil 1 set 7 days 20sets/2 weeks
TS100 average 100kgs per hour Average 500 SickBed Diesel Oil 1 set 7 days 15sets/2 weeks
TS150 average 150kgs per hour Average 750 SickBed Diesel Oil 5 sets 7 days 15sets/2 weeks
YD10 average 10kgs per hour Average 50 SickBed Diesel Oil 2sets 7 days 20sets/2 weeks
YD20C average 20kgs per hour Average 100 SickBed Diesel Oil 2sets 7 days 20sets/2 weeks
YD50C average 50kgs per hour Average 250 SickBed Diesel Oil 2sets 7 days 20sets/2 weeks
YD30 average 30kgs per hour Average 150 SickBed Diesel Oil 1 set 5 days 20sets/2 weeks
YD30 Small average 30kgs per hour Average 150 SickBed Diesel Oil 2sets 5 days 20sets/2 weeks
YD50 average 50kgs per hour Average 250 SickBed Diesel Oil 2 sets 5 days 20sets/2 weeks
YD100 average 100kgs per hour Average 500 SickBed Diesel Oil 1 set 10 days 15sets/2 weeks
YD150 average 150kgs per hour Average 750 SickBed Diesel Oil 1 set 10 days 15sets/2 weeks
YD300 average 300kgs per hour Average 1500 SickBed Diesel Oil     10sets/2 weeks
YD500 average 500kgs per hour Average 2500 SickBed Diesel Oil     5sets/2 weeks
CA 50 Mobile Containerized average 50kgs per hour Average 250 SickBed Diesel Oil 2 sets 15 days 10sets/2 weeks
HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.incinerator-scrubber.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

Incinerators QA

Q: what is kind of waste can use in this equipment?
A: This equipment for medical waste, pet animal, Municipal waste, live waste. Prohibit any 

explosive and radiation material, liquid waste and gas waste.

Q: Remedy capacityA: Average Capacity calculated by medical waste(lower calorific power (L.C.P): 3.0TH Kcal/Kg per hour), 

not mean any waste material. The animal/pet combustion rate around 2/3 of average capacity.  

Clover incinerator use time daily to 24 hours.  Between each feed/combustion time, 

there are about 0.5-1 hours cooling time and time for feeding waste. Actual combustion 
time per day is around 16 hours. The lifetime of incinerator between 5-10 year according to use. 

Generally, we proposal little lab, little clinic use capability under 20 kgs per hour. 

When incinerator use in hospital, please calculate the waste output capacity around 2kgs 
per people per day. If there are 200 sickbed in the hospital, that’s mean you need one 
incinerator capacity around 400kgs per day, change to capacity per hour is around 30-40 kgs 
per hour. According the operation time per day, waste material, budget, 
development, etc, you can use capacity from 30-50 kgs per hour incinerator.
*How to calculate Animal Cremation Burn Rate: 2/3 of the medical waste.

Q: Assembly and TestingA: We provide all documents and incinerators simple to setup and operation.  Customer 

can send people come to our factory to learn installation and operation. Generally, 
We do not send engineer to local site if not request. The dispatch cost is extra according to order.

Q: Combustion TemperatureA: The first combustion chamber: 800-1000 centi degree.The second combustion chamber: 1000-1200 centi level.

Q: Incinerator Control ModeA: Default Control mode is common control case.  PLC mode according to order and model.

Q: Operation and maintenance costsA: Operation cost according to fuel consumption rate and power/staff, etc. 

Annual around $500-$1000usd annually care according model, use scenario. 

One individual can service 02 device incinerators.  The team should have basic electrician 

knowledge to operate/inspect/maintaince incinerator/burner/blower according to 
operation user guider, and know risk of medical waste to protect worker self with necessary protection element.

Q: The Residency time in secondary combustion chamber

A: 02 sec.
WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters
Nanjing Clover Medical Technology Co.,Ltd.

Tel:  +86-25-8461 0201   

Mobile: +86-13813931455(whatsapp/wechat)
Website: www.incinerator-scrubber.com  
Email: [email protected]
Email: [email protected]  
Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity(Average) 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
1st. Chamber Temperature 800℃–1000℃ 800℃–1000℃ 800℃–1000℃ 800℃–1000℃ 800℃–1000℃
2nd. Chamber Temperature 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm

incineration Furnace for burning patalogical

CO – Shouldn’t exceed 100 mg/m3

SO2 – Shouldn’t exceed 400 mg/m3

HF – (Hydrogen fluoride) Shouldn’t exceed 9.0 mg/m3

NO2 – Shouldn’t exceed 500 mg/m3

Smoke dust  – Shouldn’t exceed 100 mg/m3

9    Height of the Incinerator – less than 10m above ground level

10    Manufacturer’s Warranty – less than 1 year

11    Electrical Connection – From closest distribution box using 25mm2 electric cable and all related connections and wiring

incineration Furnace for burning patalogical  ( such as human tissue or blood ) as west

The weight  of this west materials is 700 kg per month and we want an  isolated furnace

Without fume and any harmful gas

. INCINERATOR SPECIFICATION

# Description Specification

1    Burning Capacity – 400 kg/time and should not be less than 300 kg/time. Maximum combustion time needs to be 6 times/day

Two Chimney external diameter  – 300 to 400 mm

3    Fan power  – Shouldn’t exceed 1.1kw

4    Voltage  – 220V

5    Oil consumption  – Shouldn’t exceed 14kg/h

6    Feeding door diagonal dimension (mm)  – less than 500mm

cytotoxic waste

it’s also very important for us to know whether the unit is qualified to deal with cytotoxic waste and also the characteristics and disposal of treatment residues. Moreover, operational needs in terms of electricity and fuel consumption, as well as especially the off-gas treatment system implemented, bear significant importance, as fulfilling the requirements of Regulation 2010/75/EC is naturally necessary.

The quantity of disposal is about 100 kg per day as minimum. Bigger skills up to 500-600 kg/d will also be of great interest to us. Thus, please send us your suggestion for both aforementioned daily capacities.

The quantity of disposal is about 100 kg per day as minimum. Bigger capacities up to 500-600 kg/d are also of great interest to us. Thus, please send us your proposal for both aforementioned daily capacities.

HICLOVER INCINERATORS

Medical waste is posing a growing problem all around the world, jeopardizing the health of staff, patients, disposal employees and anyone else coming into contact with the often hazardous materials discarded by hospitals and other healthcare sites. Hospital waste varies from site to site and the biggest challenge is to dispose of this broad range of waste streams. Incineration is still the preferred way to process medical waste without endangering the heath patients, staff or anyone else coming into contact with them. Health Clinics and Health center can now manage their own waste streams using one of our specialist medical incinerators. Destroying hazardous waste at source is by far the most effective and efficient way of handling waste that may potentially spread diseases or viruses.

 

Average 20%-25% of the total waste generated by healthcare establishments is regarded as hazardous and may create an assortment of health and environmental risks if not managed and destroyed in an appropriate manner.

With years worth of expertise in this industry, our medical range of incinerators are designed to cater to the economical needs of small clinics to the demanding and technical requirements of large hospitals in their waste management processes.

 

HICLOVER is now offering a full range of medical waste incinerators, designed to offer efficient waste destruction, using best available technologies and environmentally friendly procedure. As a result of secondary chamber with its 2 minute retention interval, our medical incinerator range is ideal for process medical waste.

 

Our products guarantee efficient, clean and hassle-free disposal of medical waste is possible.

 

 

○Middle-Small Ability (TS Model)

※Main Features:

— Double Combustion Chamber

— Double Italy Burner

–Burning Rate: 10-100kgs per hour

–Combustion Chamber: 0.1M3-1.2M3

※Optional Function/Parts/Material/Burning Rate:

— Stainless Steel Chimney

— Dry Smoke Filter Chamber

— Chimney Height Custom Made

— Upgrade/Downgrade Burning Rate

 

 

○Large-Middle Ability (YD Model)

※Main Feature:

–Three Combustion Chambers

— Double Italy Burner

–Burning Rate: 30-600kgs per hour

–Combustion Chamber: 0.36M3-5.5M3

※Optional Function/Parts/Material/Burning Rate:

— Stainless Steel Chimney

— Dry Smoke Filter Chamber

— Chimney Height Custom Made

— Semi-Automatic Waste Feeding

— 3-Section Wet Scrubber System

— Movable Platform Feeding Door

— Additional Burner

— Upgrade/Downgrade Burning Rate

 

HIGH TECH PYROLYTIC MEDICAL WASTE INCINERATOR

HIGH TECH PYROLYTIC MEDICAL WASTE INCINERATOR

1.  

21. The de- ashing must be performed in the bottom of the combustion chamber or the deashing
Electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating
* A timer with flexible temporization for the regulation of every burner.
* Carcass in solid sheet steel with support of link.
* A regulator with electronic viewing for the temperature of postcombustion.
Should be Automatic or manual batch p ashing.

22. Process Filtering system: Scruber to be mentionned as optional

23. Emission Standards Compliance: BS 3316 or equal standard

23. Ability to treat Plastic: Not less than 40% by weight

24. CE Manufacturing Compliance: BS EN 746-2-1997

22. The provider must give batches of spare parts of first urgency and consumable of this
* A device of air inlet of cooling of waste gases,
Flame, lighting and security of electronic ignition, permanent ventilation, electromagnetic sluice
valve.
* A device of injection of air allowing a total recombustion of gases,
* A secondary shot of air to ensure perfect oxygen content.

19. A control box ensuring that the complete cycle of combustion.

20. Fan:
incinerator.

23. The installed incinerator must bear a 1 year guarantee.
16. The provider must provide necessary information for the best of this installation This incinerator
* A switch circuit breaker for each engine (ventilators and burners).
* Burner with fuel, mono-bloc casting guiding type with horizontal flame, lighting and security of
* The insulation of the combustion chamber should be composed of refractory bricks,
10. The lower calorific power (L.C.P) of the waste will be 3,500 kcal/kg
6.  The incinerator must avoid the release of black smoke and fine dust, (Smokeless) throughout the
9.  The incineration should be wholly free from visible smoke as well as offensive odours.
>  Nature: 65% of A1203
loadings.
Stuffing insulating out of refractor. -.
>  Nature: Calcium
•    The Temperatures of combustion: Minimum will be 850°C and max 1400°C
> Nature: 42% of A1203
5. 
3.  This incinerator must be able to destruct all combustible wastes produced by hospitals,
Private practices, laboratories, institutes, etc…
15. Fuel: diesel
Mill; it will include curative and preventive maintenance, and using equipment, etc

NB.; Civil works and any other relevant services for the installation and training of operators have to be included at the incinerator’s cost.

Specification for the refuge of the incinerator:

House of the incinerator inclusive in offer (the house must have toilet and hand washing facilities and firefighting). The size of the shelter shall measure four meter by six meter and shall be provided with adequate air ventilation.

This material and equipment must include in the shed of the incinerator: base in rubble stone, isolation roofing against humudity; elevation with brick of 20 cm (bloc cement), continuing lintel (linteau) in reinforced concrete; steel frame (charpente en metal); roof in sheet B.C.A. 28 BG

25. The technical training of operators will have to be supplied and given by a technician from the
Using a high content of aluminum and insulates bricks in order to assure a minimum
Load
* A burner of light that the use is restricted to the ignition of waste.
11. The Inner diameter of the Chimney: Ø 400 and its height: 8 m
14.
With “PYROLYTIC” combustion must possess:
*  Plate of combustion in Carborundum, preventing the fixing of glass and slags.

18. A chamber of post combustion of gases
Completed by valves and following the control of the automatic cycle.

Pet Animal Crematory Incineration

Incineration is the most obvious solution for total destruction of municipal waste, avoiding 

all the direct and indirect risks associated with other disposal methods.
Incineration perfectly fits into a trend of treating waste in a safe way, and if possible, at the 
same place where it was generated to avoid cross-contamination risk and to keep waste treatment costs at acceptable level.

— Upgrade/Downgrade Burning Rate
WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters
Nanjing Clover Medical Technology Co.,Ltd.

※Main Feature:–Three Combustion Chambers or A/B Main Combustion Chamber— Double or Three Italy Burner–Burning Rate: 80-800kgs per hour–Combustion Chamber: 1.0M3-10.0M3※Optional Function/Parts/Material/Burning Rate: — Stainless Steel Chimney — Dry Smoke Filter Chamber— Chimney Height Custom Made— Semi-Automatic Waste Feeding— 3-Section Wet Scrubber System— Movable Platform Feeding Door— Additional Burner

Mobile: +86-13813931455(whatsapp/wechat)
Website: www.incinerator-scrubber.com  
Email: [email protected]
Email: [email protected]  
Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity(Average) 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
1st. Chamber Temperature 800℃–1000℃ 800℃–1000℃ 800℃–1000℃ 800℃–1000℃ 800℃–1000℃
2nd. Chamber Temperature 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm

Tel:  +86-25-8461 0201   

Capacity of destruction in weight 60 Kg/h

Quantity: Two [2] with complete accessories.

Kinds of wastes being used: GENERAL WASTE.Polyester, polypropylene, polystyrene, vinyl acetate plastic, synthetic

plastics,
– Assumption: general hospital beds 50 percent, surgery beds 50% for the 100 bed hospital instance, while this

ratio is 30-70% for the other cases
* Frontage of loading door seals gone up on hinges, wheel of screw plug, flexible joint, and stuffing insulating

from refractory.
* A secondary shot of air to ensure perfect oxygen content.
6.     The incinerator must avoid the discharge of black smoke and dust that is fine, (Smokeless) during the loadings.
* Burner with fuel, mono-bloc casting guiding type with flat flame, lighting and security of     electronic

ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve.
* Carcass in strong sheet steel with support of connection.
Natural rubber, synthetic rubber, polyurethane sheet, and bulky films, solids and
22. Process Filtering system: Scrubber to be cited as optional
– particles that can be easily sorted
* Electro-ventilator distributing the secondary atmosphere, the regulation of the air flow being carried out by valves and

after the control of the automatic cycle.
–  global standards and waste creations assumptions should employ
Would it be possible to give us information on the capacity of incinerator we want

on this island. Incinerator to dispose our daily normal mortality for this size of the farm.1. Can the

100kg/hr burn solid waste/hazardous waste like expired paints,waste oil or chemicals.
19.     A control box ensuring the whole cycle of combustion.

20.     Fan:
23. Emission Standards Compliance: BS 3316 or equivalent standard
– Chemical waste solids and liquids, waste oil and other difficult-to-handle items

The  machines will be certified for operation from PME after passing website investigations.Manual load twin chamber

incinerator for medical waste to burn 50kg/hr on continuous operation, with Main temperature in the area of

800degC minimal and 1200degC or more in the Secondary chamber, complete with charging doorway, Ash doorway, Air and see

vents, auxiliary air system with adjustable dampers, burners and burner control system and ignition device, the whole to

meet NEMA requirements and other global standards. Здравствуйте! Стоимость и доставка до г.Алматы Казахстан

The technical details we care about are:

–          Capacity (burning capacity of waste per hour). 150kg/hour. Incinerator with 300l waste chamber

–          Construct materials, 5mm High quality light steel structure; 100 mm high quality refractory lining.

–          High Temperature paint finish.we have two hospitals,more then 20 dentist offices,and over 50 doctor offices.
5.    
Nature: Calcium
•    The Temperatures of combustion: Minimum will be 850oC and max 1400oC
21.     Controls and regulations:

medical waste incinerator solutions and prices for 100 bed / 500 mattress / 1000 mattress / 3000 bed hospitals.
23.     The installed incinerator must endure a 1 year guarantee.
•    Post combustion: >1100oC.
16.     The supplier must provide  necessary information for the best of  the setup
* Burner of light of waste, with gas, regular mono-bloc casting guiding  plunging flame, lighting and security of

electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve.
11.     The Inner diameter of the Chimney: Ø 400 and its height: 8 m
13.     The Dimension of the door for loading in cm: 70×70.
* A regulator with digital viewing for the temperature of combustion.
. Nature: 42 percent of Al203
4.     Design Specification : Types A, B, C, D, and E of medical waste
2.     It should be able to operate not less than 10 hours/day
Thickness    : ≥150 mm
* A timer with flexible temporization for the regulation of each burner.
22.     The supplier must give batches of spare pieces of first urgency and consumable of the incinerator.
* A sheath of evacuation of the gases burnt.
23. Capacity to treat Plastic: Not less than 40 percent by weight
•    Nature: Calcium silicate.
* The insulation of the combustion chamber should be composed of refractory bricks, having a high content of aluminium

and insulates bricks to be able to assure a minimum temperature on   the outside sheet metal.
* Electric box.

21. The de- ashing must be done in the base of the combustion chamber or the deashing must be Automatic or manual

batch p ashing.
9.     The incineration should be wholly free from visible smoke in addition to offensive odours.
14.    
.
15.     Fuel : diesel
Control box watertight to dust, including:

* A switch circuit breaker for each engine (ventilators and burners).
From the mill; it will include curative and preventative maintenance, and using machine, etc

18.     A chamber of post combustion of gases
3.     This incinerator must be able to destruct all combustible wastes produced by hospitals, private practices,

laboratories, institutes, etc…
* A burner of light which the use is restricted to the ignition of waste.
This incinerator with”PYROLYTIC” combustion must have:
Nature: 65% of Al203
8.     It should be able to hold emission in the second burn with gasoline residence of less than two seconds.
2. What about the heat generated during burning,are there windows or air flow into the containers.

–          Consumption of power and fuel. Hospital waste disposal system for a hospital job

–          Ash removal odor.The incinerator is for HAZARDOUS WASTE and SOLID WASTE and minimal carbon monoxide.

–          Automatic curing process temperature controlled chamber.Incinerator with 150l waste chamber

–          Secondary chamber. Have you got plans for above incinerators revealing floor dimensions,height. What materials should be used for the FLOOT, WALLS, ROOF ETC.1) The only consumable required for the system TS100

(PLC) is Oil( diesel) is that OK?

two ) from the technical specification: petroleum consumption (Kg/hour) is between 14–28) do you mean is liters/hour?

instance the incinerator will be operating for 10 hours per day means the oil consumption will be 140 Liters or more?

3) Chimney type stainless steel. How about main body construction materials?if there are more two option of body

construction materials for greater life

3. Send info about electricity, ventilation, fire protection, exhausts, chimney etc

4. Do you have prefabricated shelters?Installation of waste disposal system (biomedical) 500kg capacity model, MP 500

medical incinerator.

5. We see you have container shelters. Send us price quote for this thing

1.     Capacity of destruction in weight: 60 Kg/h.
– Items that readily degenerate such as paper, wood, leather and garbage
* A regulator with digital viewing for the temperature of post combustion.
25.     The technical training of operators will have to be supplied and given by a technician
17.     A combustion chamber of waste:
7.     It should be able to reduce the volume of wastes by 98%.

18.    A chamber of post combustion of gases
* A burner of combustion of gases,
* A device of injection of air allowing a total re-combustion of gases,
* A device of air inlet of cooling of waste gases,
* A sheath of evacuation of the gases burnt.
* Carcass in strong sheet steel with support of connection.
* Composition of the refractory;
•    Refractory concrete :
    Thickness    : ≥150 mm
    Nature: 65% of Al203
•    Insulate in fibrous panel :
    Thickness: ≥85 mm
     Nature: Calcium
* Burner with fuel, mono-bloc casting guiding type with horizontal flame, lighting and safety of     electronic

ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve.
* A secondary injection of air to ensure perfect oxygen content.
19.    A control box ensuring the complete cycle of combustion.

20.    Fan:
* Electro-ventilator distributing the secondary air, the regulation of the air flow being carried out by valves and

following the control of the automatic cycle.
21.    Controls and regulations:
Control box watertight to dust, including:

* A switch circuit breaker for each engine (ventilators and burners).
* A timer with adjustable temporization for the regulation of each burner.
* A regulator with digital watching for the temperature of combustion.
* A regulator with digital watching for the temperature of post combustion.
* Electric box.

21. The de- ashing must be done in the bottom of the combustion chamber or the deashing should be Automatic or manual

batch de ashing.
22. Process Filtering system: Scrubber to be mentioned as optional
23. Emission Standards Compliance: BS 3316 or equivalent standard
23. Capacity to treat Plastic: Not less than 40% by weight
24. CE Manufacturing Compliance: BS EN 746-2-1997
22.    The supplier must give batches of spare parts of first urgency and consumable of the incinerator.
23.    The installed incinerator must bear a one year guarantee.
24.    The supplier shall perform an onsite installation of the incinerator.
25.    The technical training of operators will have to be provided and given by a technician
from the factory; it will consist of curative and preventive maintenance, and the use of machine, etc

HICLOVER Made Waste Incinerators

HICLOVER, Nanjing Clover Medical Technology Co.,Ltd, supply system solutions for medical environmental protection, animal and pet cremation engineering, other municipal solid waste incineration project.

We provide single combustion chamber, double combustion chambers, three combustion chambers and multi-combustion chambers waste incinerators for laboratory, clinic, hospital, medical center, hygiene clinical waste destruction with medical disposable, biological waste, medical plastic waste, hazardous waste, red bag waste, needle disposal, gauze and bandages, sealed sharp containers, pathological waste, trace-chemotherapeutic wastes, etc..

      

Our range of incinerators cater for small to large scale animal cremation related businesses, such as poultry farms, cattle farms, sheep farms, pig farms, stables, kennels, testing laboratory, catteries, pet crematoriums.

The incinerator burn waste in primary combustion chamber and burn the smoke from primary combustion chamber again to make sure environmentally friendly with no black smoke, smelless, reduce pathogenic bacteria infection.

Incinerator capable of treating between 300 & 500 kgs fitted Using the wet scrubber system

Automatic loading and reloading with capacity of 10 to 12 tons per day working with gas treatment procedures and gasoline fuel and should comply with the European Standards.the Government Hospital for Medical Waste Incinerator with these Specifications. They’re having general wastes like cells, plastic bottles ,wastes coming from labour camps, to be incinerated, they want, 50kg/hr incinerator
2. Temperature
One of the major deciding factors of the potential provider is the energy consumption of the plan, indicated either per hour or per day and I would appreciate if such information can be made available.

Incinerator factory

Key Features:

General Municipal Solid Waste Incinerator, Pet and Animal Cremation, 

Containerized Mobile Incinerator, High Efficient Environmental Waste Incinerator.
— Single combustion chamber, double combustion chambers, three combustion chambers and 
multi-combustion chambers waste incinerators.
— System solutions for medical waste environmental.
— High burn rate, from 5kgs to 1000kgs per hour.
— New Design for pet animal cremation business.

— HICLOVER, trusted partner with years of experience.

WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters
Nanjing Clover Medical Technology Co.,Ltd.

— Full range incinerator with Economized Small Scale incinerator, Standard Small-Large Scale incinerator, 

Mobile: +86-13813931455(whatsapp/wechat)
Website: www.incinerator-scrubber.com  
Email: [email protected]
Email: [email protected]  
Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity(Average) 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
1st. Chamber Temperature 800℃–1000℃ 800℃–1000℃ 800℃–1000℃ 800℃–1000℃ 800℃–1000℃
2nd. Chamber Temperature 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm

Tel:  +86-25-8461 0201   

Animal body parts,other biomedical waste,organs dung

13.     Civil    works,    installation    and
Comnuss!Onmg    lndusive  of  civil  works  (brick  wall  incinerator  house
Type of waste for disposal    Animal  body  parts,other  biomedical  waste,organs dung, bedding materials,plant p缸ts and meals itemsι
bidding document

51. No    Features    $_pecific tions
6.    
11.     Opening lid    Large top open归g lid (Approx. 700 mm x 500mm) for
Model of the incinerator.
Of those quoted  incinerator  must  be  included  in  the
Lnstallation and commissioning of the incinerators including hiring of heavy machineries requ让ed at the time of instalIation.
7.     Secondary chamber    Slid heath

HICLOVER Waste Incinerator Front view

— Full range incinerator with Economized Small Scale incinerator, Standard Small-Large Scale incinerator, General Municipal Solid Waste Incinerator, Pet and Animal Cremation, Containerized Mobile Incinerator, High Efficient Environmental Waste Incinerator.

— System solutions for medical waste environmental.

— High burn rate, from 5kgs to 1000kgs per hour. — New Design for pet animal cremation business.

— HICLOVER, trusted partner with years of experience.

Nanjing Clover Medical Technology Co.,Ltd..

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity(Average) 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
1st. Chamber Temperature 800℃–1000℃ 800℃–1000℃ 800℃–1000℃ 800℃–1000℃ 800℃–1000℃
2nd. Chamber Temperature 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm

WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters

Tel:  +86-25-8461 0201   Website: www.incinerator-scrubber.com  Email: [email protected]Email: [email protected]  

Tel:  +86-25-8461 0201   
Website: www.incinerator-scrubber.com  
Email: [email protected]
Email: [email protected]  

Containerized Mobile Incinerators

○ Containerized Mobile Incinerator(CA Model)

HICLOVER now offer a full range of containerized incineration systems, placing us at the forefront of the latest transport and industrial trends. Containerization enables immediate waste management as the units are pre-assembled and pre-installed.

Containerization is the most feasible and viable option in contrast to the construction of on-site facilities and housing structures, eliminating the man power and costs involved. The system has the added benefit of total mobility (both international and local ), and is excellent for civil and military camps and remote locations where infrastructure is scarce.

 

※Main Feature:

— Dual Combustion Chamber

— Dual Italy Burner

–Burning Rate: 10-100kgs per hour

–Combustion Chamber: 0.1M3-1.2M3

— Mobile Incinerator, Standard shipping containers, Easy to move/transport system

— Free Setup, Pre-installed incinerator, Ideal for decks

— Ultraviolet lamp sterilization inside

※Optional Function/Parts/Material/Burning Rate:

— Stainless Steel Chimney

— Dry Smoke Filter Chamber

— Chimney Height Custom Made

— Upgrade/Downgrade Burning Rate

a pet incinerator for the cremation of dogs

We’ve got a 70 bed hospital in namibia. However there is a potential of getting clients from other regional doctors.
A tiny incinerators (ex. Please see attached) for a few empty chemical luggage. Can you please provide me with some details information about these type of incinerators (small scale). A pet incinerator for the cremation of dogs and cats. It’ll be single use of each pet seperately.Initially we’re planning to begin this Pilot Project with the National Hospital, to convince the Ministry Officials and on its achievement to take this project to the Teaching Hospitals, District and Base Hospitals at the Country.municipality need 4 crematory machine for cadavers. I need some information regarding cost,  kine of energy for detection,toxic emission,The incinerator we’re looking should be with the advantages of Heat recycling system, utilization of hot water, etc.. Capacity — 150-200 kgs/hr and with International standards.get more information about the Pet Cremation Equipment, especially for dogs and cats.

The three incinerators for burning and incineration of drugs and toxic substances

Requirements and specifications for the process of distribution, installation, operation and guarantee the three incinerators for burning and incineration of drugs and toxic materials for customs department

Free three years guarantee for incinerators from delivery date. Along with free spare parts guarantee letter ought to be valid for 10 years from the end date of guarantee.
•    This umbrella Cover the site furnace and let bringing the chimney
In case of order, we need two certificates of origin that should be stamped from Saudi embassy in your country
•    All gear must be resistant to external conditions like high temperature (50oc)
•    All doors should have special lock aren’t allowed non-persons appointed to do the job.
Commercial statement (certified from Chamber of Commerce)
•    The dimensions of the base are increased by (2 meters) from the edge of incinerators
Send someone to fix and train our employees for 5 people in each location
4-copmany must committed delivery, operation, and installation within 60 days from the date of site projects detection
•    Incinerators must have a system for processing (purification) gasses before emission of the smoke.
•    The remaining accessories in all the trends even allows the worker directly feeding and maintenance work, cleaning and move easily taking into consideration the tendencies of the foundation toward the doorway for drainage of water.
1-Technical explanation includes technical specifications, scope of work, the demands of the maintenance and operation.
2- Technical explanation for technicians training and furnace operators
The company must make all the maintenance work as well adjustment of the control and protection devices and filters / filters purify insulation
•    Ensure that the combustion of substances emitted from the secondary room should be at least two seconds period and the room is lined with high-density ceramic fibbers

The offer price must include the following;-
1. Training for technicians and operators for a period not less than two days at each site and give trainees training certificates
Documents must contain all the information such as brochures, technical resources, operating, maintenance manuals, and brochures dealing with the keyboard
2- Letter from the manufacturer to give three years guarantee for incinerators from delivery date. In addition of free spare parts guarantee letter should be valid for 10 years from the end date of guarantee
3- Provide certificate that the incinerators are environmentally friendly and attach proof that environmental protection organizations in the country of Origin and your product should be emissions free due to the sensitivity of its international air ports.
4-copmany must committed delivery, operation, and installation within 60 days from the date of site projects detection
5- Train five people for two days for each device for a period of two days for installation, operation, and safety. Give them certificates
GARANTEE
Provides operating and emergency maintenance also provides free spare parts for three from the starting date of the project. The company must make regular maintenance every 3 months and raise the maintenance report to the management of public concern and Maintenance.
The company must make all the maintenance work as well adjustment of the control and protection devices and filters / filters purify insulation
Specifications of ovens:
•    Installing a readymade concrete base (Precast) with Height 30 cm above the ground and 20 cm below the surface of the earth.
•    The dimensions of the base are increased by (2 meters) from the edge of incinerators
•    The rest of the accessories in all the trends even allows the worker directly feeding and maintenance work, cleaning and move easily taking into account the tendencies of the base toward the door for drainage of water.
•    The floor coating must be high-quality epoxy paint.
•    Install anti-rust and heat Umbrella of brick and steel (pyramid shape) of (5) meters height above the ground which installed with the edge of the concrete base by thick galvanized columns
•    This umbrella Cover the site furnace and allow bringing the chimney
•   The site is surrounded by an iron fence (sheet metal) 3 meters height from the surface of the earth in order to protect the incinerators from dust storms
•    The iron fence must have a 5 meters Width gate
•    Automatic anti-rust and heat electrical circuit must be provided
•    The furnaces are highly efficient, emissions-free, safe, and environmentally friendly and have capacity of not less than 3,000 kg of materials and the rate of burning at least 400 kg / h
•    The method of feeding the furnace through a side slot or from the top and the emission of the smoke is completely prevented.
•    a furnace Must have two rooms, one of them is the  main room of not less than the “5” stoves to the process of burning materials and other secondary room of not less “2” stoves to burn resulting gas from the first process as well as the chimney
•    The main component of the body of the furnace is stainless steel box, the thickness of not less than 7 mm with a layer of zinc phosphate plated with aluminium reflector to heat
•     the thickness of the door of 150 mm and a hardness of not less than 170 kg / m 3 to be burnt, automatic comprehensive remote system.
•    Furnaces must be destructive enough to burn and incinerate the material which mentioned previously
•   furnaces must have certificates are supported global enterprises and government competent for environmental protection In the country of origin or the General Presidency of Meteorology and Environment Protection in Saudi Arabia
•    The oven can work for 24 hours so as to allow for the burning of materials for a period of not less than 12 consecutive hours and the remainder for cooling and provides full fuel tank with a capacity of 1000 L to turn on the oven.
•    Must have an automatic ignition and diesel is used
•    a furnace has the ability to withstand extreme temperatures up to “130o c And also, it guarantees continuous operation of which can be utilized for 24 hours with the ability to remove residues during the work of the oven, Insulating layer of calcium must be present in the rooms with Thickness not less than 50 mm and a wall thickness of 100 mm
•    Isolation of burning room: the space between the walls must be of the “stainless steel”. In addition, burn room must fill with Thermal insulation material.
•    Ensure that the combustion of materials emitted in the secondary room should be at least two seconds period and the room is lined with high-density ceramic fibbers
•    Incinerators must contain a system for processing (purification) gasses before emission of the smoke.
•     Incinerators must have the capacity of self-cooling after the end of the daily operating period.
•    Incinerators must have chimney not less than “4 meters” height from the surface of the oven, also, it must be thermally insulated and non-rust able, and must also be removable, installation and tide default.
•    Electrical capacity required “220/ 380-volt “60 hertz
•    Incinerators must be fitted with a control panel of the electronic keys to monitor all the necessary indicators of activation keys, as well as start-up and switch off so as to be isolated inside a metal box with the presence of the following:
Alarm Sensor in the event of (crashes “burner” or purification device or heat leakage       or internal connections and wiring)
Monitors for the temperature of the rooms
Aerosols Filter indicators/ monitors
Room temperature sensors
Indicators for furnaces and index overload
Timer for Extinguish the oven automatically depending on the time required.
•    All equipment must be highly resistant to external conditions such as high temperature (50oc)
•    All doors must have special lock are not allowed non-persons appointed to work.
•    Providing fire extinguisher for each site with a capacity of 10 kg at least

WASTE INCINERATOR

 

–          150 KG/HR

–          Compliant with EU rules, Directive 2000/76/EC

–          Fuel type: Diesel

–          Easy management and maintenance

–          Temperatures:

850 deg C for municipal waste

1000 deg C for medical waste

1100 deg C for harmful waste containing halogenated organic substances with content of chlorine or its compounds.

Medical Waste Incinerator BID

1. Technical specifications;

I. Size of the Incinerator 4,410W x 3,037L x 4,836H mm

II. Ability of the Incinerator Medical waste 50 kg/hr. Batch feeding (low level caloric value: 4,000 5,000kcal/kg)

III. Utility

Utility condition for the incineration equipment operating is the following.

1) Gas: Light oil or Kerosene

2) Electricity

Motor

-0.1 — 110kW: AC 220V x 3PH x 50Hz

– Below 0.1kW: AC 220V x 1PH x 50Hz Control Circuit

– MCC controller: AC 220V x 1PH x 50Hz

– Instrument: AC 220V x 1PH x 50Hz

– Switch Gear: AC 220V x 1PH x 50Hz

2. Door -to-door transportation, Installation, Commissioning and Training

3. Pricing quotation

– Price has to be supplied in Ethiopian Birr (incl. VAT)

– Price should include additional cost elements such as freight, insurance, installation and training for key human resource, until acceptance duty where applicable